22TS.3 20PS

 

Sorry, this entry is only available in English and Français. For the sake of viewer convenience, the content is shown below in this site default language. You may click one of the links to switch the site language to another available language.

Srah Srang (APSARA)

ICC–Angkor recommends:

a. Demolish the upper concrete slab, currently in a damaged state;
b. Repair the lower fill with insertion of a geotextile and geogrid device, along the principle of compacted earth as used by the Italian team on the Angkor Wat moats or as is being done by the French-Khmer team at the Western Mebon site, which would make it possible to ensure a proper level of stability while preventing sand from being drawn out by water infiltration;
c. Replacement of the upper reinforced concrete slab using stainless steel reinforcement prior to final repositioning of the slab and the steps arrangement;
d. Invite the team implementing this project, which has extended over many months, to pull itself together with an eye to efficiency and greater performance to complete quickly this project.